Buchi Logo
  • Product Families
    • Industrial Evaporation
      • Rotavapor R-220 SE
      • Rotavapor R-220 EX
      • Rotavapor R-250
      • Rotavapor R-250 EX
      • Chiller for R-220 SE
    • Evaporation Solutions
      • Rotavapor® Systems
      • Rotavapor® R-210/R-215
      • Rotavapor® R II
      • Rotavapor® R-3
      • Rotavapor® - Previous models
      • Vacuum Solutions
      • Vacuum Pump V-700
      • Vacuum Pump V-710
      • Vacuum Controller V-850/V-855
      • Vacuum Modules EasyVac
      • Vacuum Modules LabVac
      • Glass Oven B-585 Kugelrohr
      • Glass Oven B-585 Drying
      • Recirculation Chiller
    • Spray Drying & Encapsulation
      • Nano Spray Dryer B-90
      • Mini Spray Dryer B-290
      • Inert Loop B-295
      • Dehumidifier B-296
      • Encapsulator B-390 / B-395 Pro
    • Melting Point
      • Melting Point M-560
      • Melting Point M-565
      • Sample Loader M-569
    • Parallel Evaporation
      • P-6/12 Multivapor
      • Syncore Polyvap
      • Syncore Analyst
      • SPE & Evaporation
    • Parallel Reactors
    • Flash Chromatography
      • Manual Controlled Systems
      • Computer Controlled Systems
      • Applications
      • Preconfigured
    • Extraction Solutions
      • Classical Extraction
      • Pressurized Solvent Extraction
      • Sample Preparation
    • Kjeldahl Solutions
      • Digestion
      • Distillation
      • Wet Digester B-440
      • Scrubber K-415
      • Kjeldahl Tablets
    • NIR Solutions
      • NIRFlex
      • NIRMaster
      • NIRWare
      • NIROnline
      • NIRCal
      • NIR Applications
  • Applications
    • Search
    • Evaporation & Separation
    • NIR Pre-Calibration
    • Spray Dryer Application Finder
    • Kjeldahl
    • Extraction
    • best@buchi
    • Literature
    • Application Support
  • Service & Technical Support
    • Service & Repair Support
      • Service Centers Map
    • Technical Support
      • Search
      • Evaporation & Separation
      • NIR Pre-Calibration
      • Spray Dryer Application Finder
      • Kjeldahl
      • Extraction
      • best@buchi
      • Literature
      • Application Support
    • Contact
  • Sales Contacts & Information
    • Sales Contacts
      • Alabama
      • Alaska
      • Arizona
      • Arkansas
      • California
      • Colorado
      • Connecticut
      • Delaware
      • Florida
      • Georgia
      • Hawaii
      • Idaho
      • Illinois
      • Indiana
      • Iowa
      • Kansas
      • Kentucky
      • Louisiana
      • Maine
      • Maryland
      • Massachusetts
      • Michigan
      • Minnesota
      • Mississippi
      • Missouri
    • Authorized Distribution Partners
      • Fisher Scientific USA
      • VWR International
      • Sigma Aldrich
      • Thomas Scientific
      • Cole-Parmer
      • Krackeler Scientific
      • Spectrum Chemicals & Laboratory Equipment Products
      • Daigger
      • Capitol Scientific
      • Scientific Equipment Company
      • Pacific Star Corporation
    • Buchi Team
    • Company Profile
    • Vision
    • Worldwide
    • Events
    • News
    • Company & History Movies
    • Visiting BUCHI Corporation
    • Careers
    • Trademarks
  • Basket
    • Request quotation
    • Request service contract
    • Purchase consumables online
Homepage > Product Families > Spray Drying & Encapsulation > Process

Spray Drying & Encapsulation

Spray Drying Workshop

BUCHI Corporation and TA Instruments are excited to host industry leaders in the field of Spray Drying.

Get hands-on experience, learn from industry leaders, and network with your collegues.

Wed-Thurs, Apr 25-26, 2012

 Find out more..

 
  • Products
  • Applications
  • Spray Chilling
  • Process
  • Theory
  • Scale-up

Spray drying involves evaporation of moisture from an atomised feed by mixing the spray and the drying medium. The drying medium is typically air. The drying proceeds until the desired moisture content is reached in the sprayed particles and the product is then separated from the air. The mixture being sprayed can be a solvent, emulsion, suspension or dispersion.

Here all the detail are brougth together - the functional principle of the Mini Spray Dryer B-290

 

 

 

 

  1. Air intake
  2. Heating
  3. Temperature sensor at air entry point
  4. Two fluid nozzle
  5. Flow- Stabilized entry into the drying chamber
  6. Temperature sensor at air exit point
  7. Cyclone: separation of the product from the air stream
  8. Collection vessel for finished product
  9. Aspirator

The B-290 two fluid nozzle


The intelligent design of the B-290 reduces preparation and cleaning times to a minimum! That  means more productivity and efficiency in the current development process. The details of the innovative nozzle are:

 

 

  • Automatic nozzle cleaning is a standard feature occurring at selected time intervals or by manual intervention
  • The nozzle is fitted with a ruby point to meet the highest quality requirements
  • The design of the nozzle is optimized for simple disassembly
  • A simple cleaning procedure using a special cleaning brush
  • All parts made of stainless steel are corrosion resistant
  • The nozzle can be sterilized

Example:

100 ml of a solution are sprayed, resulting in approx. 8 x 108 = 800,000,000 drops (25 microns) representing approx. 12 m2 of surface area. This clearly demonstrates that the solvent (mainly water) is vaporized extremely quickly.

Cyclone technology


The glass cyclone used as a separator is a dust collection device widely used in industry for more than a century. The main advantages are its simple construction and absence of moving parts. Separation is based on the inertial deposition of the particles from the gas stream. In the reverse flow cyclone, the gas is made to spin by introducing it tangentially. This produces centrifugal forces up to hundred to thousand times greater than gravitational force. The particles move towards the wall and the base of the cyclone, while the gas spirals upwards to the gas outlet at the top of the cyclone.

BUCHI Labortechnik offers a bench-top Spray Dryer with glass cyclone incorporating an electrically conductive layer to prevent electrostatic binding and thus product loss in the cyclone. The effect of this coating strongly depends on the material properties, e.g. for proteins, no difference can be detected, whereas for lactose as a typical matrix substace in pharmaceutical applications, the difference in separation performance is obvious.

BUCHI offers two diferent kinds of cyclones. The standard cyclone for standard applications with particles in the range of 3 µm to 25 µm and a high performance cyclone for small sample amounts and better yields also for smaller particles down to 1 µm.

Dependance of inlet and outlet temperature


Inlet temperature is understood as being the temperature of the heated drying air. The drying air is sucked or blowed in over a heater by the aspirator. The heated air temperature is measured prior to flowing into the drying chamber. When spray drying a solution, emulsion or dispersion the solvent is removed by vaporization.

The temperature of the air flow does not have to be higher than the boiling point of water to evaporate the individual drops during the short residence time. The gradient between wet surface and not saturated gas leads to an evaporation at low temperatures. The final product is separated and has no further thermal load.

The temperature of the air with the solid particles before entering the cyclone is designated as the outlet temperature. This temperature is the resultig temperature of the heat and mass balance in the drying cylinder and thus cannot be regulated. Due to the intese heat and mass transfer and the loss of humidity, the particles can be regarded to have the same temperature as the gas. Thus, as a rule of thumb is: outlet temperature = max. product temperature. Due to this fact spray drying is a very gentle methode to dry powders.

For more background information about Spray Drying please see the files that can be downloaded in the sector theory.

  • Top of page
  • Privacy
  • Contact us
  • Sitemap
  • Partnernet
  • Print
  • © 2012 BÜCHI Labortechnik AG
BÜCHI Labortechnik AG Logo BUCHI Corporation
19 Lukens Drive, Suite 400
New Castle, DE 19720
USA


www.mybuchi.com
us-sales@buchi.com
Tel: +1 302 652 3000
Fax: +1 302 652 8777

© 2006 BUCHI Corporation    
last modified: April 17 2012
  • USA
  • Worldwide

Contact Buchi

Do you want to:

  • Request more information
  • Talk to a specialist
  • Email a sales person
  • Where to buy
  • Order a print brochure
Configure your product

Product information

  • Mini Spray Dryer B-290 (pdf, 492.34k)
  • Products & Solutions EN (pdf, 1.33Mb)
  • Training Papers Spray Drying (pdf, 715.28k)
  • Quick Operation Guide (pdf, 62.14k)

8th annual technical seminar and workshop


Thursday, May 24, 2012
Holiday Inn
Somerset, NJ

Learn essential technical information and participate in open discussions on implementation, application and method development among users and peers, with hands-on demonstrations.
 click for more details

NEW BUCHI WebStore

 Order parts and commonly used equipment

Webinars


 View webinar archive

Stay up to date

Subscribe to our newsletter 

Your account

Login


Forgot your password?Not a member? Join now.Why register a Buchi ID?

Your feedback

    Rate this page